Pricing Contact Log in Book a demo Get started

Fermentation readings form

Your fermentation reading form is the form you fill in when recording a reading against a batch, either from the batch's Analysis tab or from the production dashboard. You control which readings appear on it, which of them are compulsory, and the units they are recorded in, at Settings -> Production settings -> Fermentation readings form.

The reading types available

Breww supports a long list of reading types. Gravity, vessel temperature, vessel temperature 2, vessel set temperature and pH are listed first, followed by the rest in alphabetical order: apparent density (steel), bitterness, cell count, CO₂, colour, conductivity, diacetyl test, dissolved oxygen, haze, haze percentage, N₂, observations, pressure, sulphur, titratable acidity and VDK.

Each one is a row on the settings page with three columns you can change.

Show reading form

Tick this to have the reading type appear on your fermentation reading form. Untick it to hide it.

Out of the box, Breww shows Gravity, pH, Vessel temperature and Observations, and hides everything else. Turn on whichever extras your brewery records.

Require reading if shown

Tick this to make the reading compulsory whenever the form is filled in. Anyone recording a reading will not be able to save it until that field has a value.

By default only Gravity is required. This is worth thinking about carefully: if you make several readings compulsory, a quick check on the tank floor becomes a longer job, and people may end up entering placeholder values just to save the form.

Unit of measurement

For reading types that are measured, this chooses the unit the reading is entered and displayed in, for example specific gravity or degrees Plato for gravity, and Celsius or Fahrenheit for temperature. The unit you pick also determines the sensible range and number of decimal places Breww will accept for that reading.

Breww picks a sensible starting unit for you, and breweries with a US address start with Fahrenheit for temperatures rather than Celsius.

Two reading types, Observations and Diacetyl test, are free text rather than a measurement, so they have no unit and show a dash in this column.

Saving your changes

Change as many rows as you need and then select Save batch reading settings at the bottom of the page. The changes take effect immediately, on both the web app and the Breww mobile app.

Still stuck?

Tell us what you are stuck on.

These guides are written for the breweries who run Breww, so parts of them will describe screens you do not have. Send us the details and we will point you the right way.

Please use the routes above rather than replying to a sales email, support does not reach us that way.

Book a demo

Tell us where you are based so we can match you with the right person.

Loading...